tissue culture
lab equipment laboratory laboratory equipment
 
laboratory supplies
Orange Scientific logo HOME | CONTACT
 
 
 
fisher scientific instruments equipment
Liquid Handling Liquid Handling  Liquid Handling Menu
TIPOR-VN TIPOR-VL
   

Single Channel Adjustable Volume Micropipettors

TIPOR-VN
Without Locking Mechanism

TIPOR-VL
With Locking Mechanism


As with all its other ranges, Orange Scientific goal is to offer high tech products, at the best quality, giving added value and innovative features to the user, all at a equitable price. All TIPOR-VN & TIPOR-VL offer the following features:
  • The TIPOR-VN & TIPOR-VL are volumetric instruments designed to measure and transfer liquids precisely and safely. It can measure and transfer volumes from 0.2l to 10000l depending on the model.
  • Locking mechanism on TIPOR-VL ensures that no accidental volume modification can occur.
  • Features Super Low Pipetting Forces. Our TIPOR-VN & TIPOR-VL feature significantly lower pipetting forces than the average pipetting forces in the market.
  • A special handle has been designed for comfort of use during long hours.
  • Volume setting by either the volume control button or the Push button.
  • Volume colour code on Push button allows easy volume identification.
  • The length of the tip ejector can be regulated by +1mm or +2mm. The ejector itself can be removed when working with narrow tubes.
  • Fully Autoclavable.
  • TIPOR-VN & TIPOR-VL should not normally be adjusted. However, they are designed to be easily in-lab calibrated and include a free calibration tool with each instrument.*
  • Orange Scientific offers a calibration service in its laboratory. Please contact you local distributor for details.*
  • A 3 year warranty covers each product.

* Calibration of pipettors means determining the difference between the dispensed volume and the selected volume. Adjustment means altering the pipettor so that the dispensed volume is within the specifications. Usually the word calibration is understood as adjusting the pipettor, and therefore, calibration, as used in this text, means testing and adjusting.

Free micropipettor hanger and calibration tool included with every micropipettor






6 Places stand is available: cat # 3540210


Cat# TIPOR-VN Cat# TIPOR-VL Volume (l) Inaccuracy (%) Imprecision (%) Fits to tip (l) / colour) Colour
Code
3610100 3620100 Min 0.2
1.0
Max 2.0
12.0
2.7
1.5
under 6.0
under 1.3
under 0.7
10 l / neutral Red
3610105 3620105 Min 0.5
5.0
Max 10.0
4.0
1.0
0.5
under 2.8
under 0.6
under 0.4
10 l / neutral Red
3610110 3620110 Min 2
10
Max 20
3.0
1.0
0.8
under 1.5
under 0.5
under 0.3
200 l / yellow Purple
3610112 3620112 Min 5
25
Max 50
2.5
1.0
0.8
under 2.0
under 0.6
under 0.4
200 l / yellow Green
3610115 3620115 Min 10
50
Max 100
1.6
1.0
0.8
under 0.8
under 0.24
under 0.2
200 l / yellow Orange
3610120 3620120 Min 20
100
Max 200
1.2
0.8
0.6
under 0.6
under 0.25
under 0.2
200 l / yellow Yellow
3610125 3620125 Min 100
500
Max 1000
1.6
0.7
0.6
under 0.45
under 0.25
under 0.25
1000 l / blue Blue
3610130 3620130 Min 1000
2500
Max 5000
0.6
0.6
0.5
under 0.25
under 0.2
under 0.15
5000 l / neutral Turquoise
3610135 3620135 Min 1000
5000
Max10000
2.5
0.8
0.5
under 0.6
under 0.3
under 0.2
10000 l / neutral White

Measurement conditions: distilled water at temperature 20C 1C



   
   
 